Schneider Easy UPS 160kVA-E3MUPS160KHS


160kVA Online Double Conversion Easy UPS kVA = kW 3Ph input 3 Phase output

  • Easy-to-install, easy-to-connect, easy-to-use, and easy-to-service 160 kVA 3 phase UPS with advanced product features, robust electrical specifications and compact …
  • Includes: Dust filter, Installation guide, Start-Up Service

E3MUPS160KHS  Features

Output
Max Configurable Power (Watts)
160.0kWatts / 160.0kVA
Output Voltage Distortion Less than 3 %
Output Frequency (sync to mains)
50 Hz Sync to mains, 60 Hz Sync to mains
Other Output Voltages 380, 415
Topology
Double conversion online
Waveform type Sine wave
Overload Operation 10 minutes at 125% and 60 seconds at 150%
Output Voltage THD
< 3% linear load and < 5% non-linear load
Output Voltage Tolerance +/- 1 %
Input
Input frequency 40 – 70 Hz
Input voltage range for main operations 342 – 477V
Input Total Harmonic Distortion Less than 3 % for full load
Other Input Voltages 380, 145
Maximum Short Circuit Withstand (Icw) 10.0kAmps
Input Power Factor at Full Load 0.99
Batteries & Runtime
Battery type External battery system
Communications & Management
Interface Port(s)
E3M_ColdStart, E3M_parallel
Control panel Touch screen LCD user interface
Audible Alarm Audible and visible alarms prioritized by severity
Physical
Maximum Height
1300MM, 130.0CM
Maximum Width
500MM, 50.0CM
Maximum Depth 850MM, 85.0CM
Net Weight
227.0KG
Shipping weight
257.0KG
Shipping Height
1500MM, 150.0CM
Shipping Width
625MM, 62.5CM
Shipping Depth
975MM, 97.5CM
Color White
Environmental
Operating Temperature 0 – 40 °C
Operating Relative Humidity
0 – 95 (Non-condensing) %
Operating Elevation 0-1499.9meters
Storage Temperature -25 – 55 °C
Storage Elevation 0-15240meters
Audible noise at 1 meter from surface of unit
72.0dBA
Online thermal dissipation
27297.0BTU/hr
Protection Class IP20
Conformance
Approvals
EN/IEC 62040-1, IEC 62040-2, IEC 62040-3, IEC 62040-4
Standard warranty 1 year on-site repair or replace with factory authorized Start-Up
Sustainable Offer Status
RoCH Complaint
Weight 256.464 kg
Dimensions 97.5 × 62.5 × 150 cm
Power Capacity (VA)

120000 – 160000 VA

Power Capacity (Watts)

120000 – 160000 Watts

Battery Type

Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof, VRLA

Output Connection Count

1, 3, 4

Regulatory Approvals

BIS, BIS Approved, CE

Input Connection Type

India 3-pin 6A, Indian/South African BS 546A

Topology

Line Interactive, Square

Technical Specifications

Output
Max Configurable Power (Watts) 360Watts / 600VA
Output Frequency (sync to mains) 47 – 63 Hz
Topology Line Interactive
Waveform type Stepped approximation to a sinewave
Input
Input frequency 47 – 63 Hz
Input voltage range for main operations 145 – 290V
Number of Power Cords 1
Batteries & Runtime
Battery type Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
Typical recharge time 6hour(s)
Replacement Battery APCRBC110
Battery Charge Power (Watts) 14Watts
Battery Volt-Amp-Hour Capacity 86
Communications & Management
Control panel LED status display with On Line : On Battery : Replace Battery and Building Wiring Fault
Audible Alarm Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm
Surge Protection and Filtering
Surge energy rating 255Joules
Physical
Maximum Height 218MM, 21.8CM
Maximum Width 107MM, 10.7CM
Maximum Depth 237MM, 23.7CM
Net Weight 4.7KG
Shipping weight 5.2KG
Shipping Height 295MM, 29.5CM
Shipping Width 165MM, 16.5CM
Shipping Depth 310MM, 31.0CM
Environmental
Operating Temperature 0 – 40 °C
Operating Relative Humidity 0 – 95 %
Operating Elevation 0-3000meters
Storage Temperature -15 – 45 °C
Storage Relative Humidity 0 – 95 %
Storage Elevation 0-15000meters
Audible noise at 1 meter from surface of unit 45.0dBA
Conformance
Approvals BIS Approved
Standard warranty 2 years repair or replace
Sustainable Offer Status
REACH REACH: Contains No SVHCs